KODE RAHASIA POMPA TATSUNO
| No. | Display | Check | Tindakanponpeskarangmojo.com |
| 1. | No indicator on both front and rear display. | Confirm the power switch | Check the power switch to ON position |
| Confirm the fuse on the “power supply” | Exchange the power supply unit | ||
| Check on the “connector and wiring” | Modify or exchange | ||
| Confirm the output of DC and AC power from “Power supply” | Exchange the “Power supply unit” | ||
| Check “CPU board” | Exchange the “CPU board” | ||
| 2. | .Light on only one side of display. | Check on the “connector and wiring” | Modify or exchange |
| Confirm the input voltage of “Display board” | Check the input voltage on the “Display board” (from CPU board and power control board) | ||
| Check “Display board” | Exchange the display board | ||
| Check “CPU board” | Exchange the CPU board | ||
| 3. | No light on display except some digits (not all digits) or Strange numbers are displayed. | Check on the “Connector and wiring” | Modify or exchange |
| Check “Display board” | Exchange the “Display board” | ||
| Check “CPU board” | Exchange the “CPU board” | ||
| 4. | Displaying figures can not be reset to zero (all 8-blank-0) even if the nozzle switch was turned on. | [in case of the motor doesn’t rotate] | |
| Confirm the unit price and unit address | Register the unit price and unit address | ||
| Check “Nozzle switch” and wires | Confirm the position of the switch is at OFF. Modify or exchange | ||
| Check the communication with POS | Confirm that authoritative signal is received, when the communication with POS is designated in computer | ||
| Check “CPU board” | Exchange the CPU board | ||
| [in case of the motor rotates] | |||
| Check the connector and wiring | Modify or exchange | ||
| Check “CPU board” | Exchange the CPU board | ||
| Check “Display board” | Exchange the display board | ||
| 5. | The displayed volume is different from actual delivered volume. | Check “Connector and wiring” | Modify or exchange |
| Check “Pulser” | Exchange the pulser | ||
| Check “CPU board” | Exchange the CPU board | ||
| Check “Power control board” | Exchange the power control board | ||
| Check “Solenoid valve” | Modify or exchange the solenoid valve | ||
| 6. | The motor stops during the fuelling. | Check “Connector and wiring” | Modify or exchange |
| Confirm if instantaneous power failure occurred | Turn off the nozzle switch | ||
| Confirm the error from the pulser | Exchange the pulser | ||
| Check “Pump relay” | Exchange the relay | ||
| Check “Power control board” | Exchange the power control board | ||
| Confirm the output of DC power at the “Power supply unit” | Exchange the power supply unit | ||
| Check the “Nozzle switch” | Readjust or exchange the nozzle switch (micro switch) | ||
| Check “CPU board” | Exchange the CPU board | ||
| 7. | The motor doesn’t stop after turning on the “Nozzle switch”. | Check the “Connector and wiring” | Modify or exchange |
| Check “Nozzle switch” | Modify or exchange | ||
| Check “CPU board” | Exchange the CPU board | ||
| Check “Pump-relay” | Exchange the relay | ||
| 8. | The solenoid valve doesn’t work properly. | Check the “Connector and wiring” | Modify or exchange |
| Check “Solenoid valve” | Modify or exchange | ||
| Check “CPU board” | Exchange the CPU board | ||
| 9. | Input data is gone out by remote controller. | Check the remote controller | Adjust the distance between the remote controller and its receiver |
| Check the password | Check the password in maintenance mode | ||
10. | Cannot use “Preset unit”. | Check “Connector and wiring” | Modify or exchange |
| Check “CPU board” | Exchange the CPU board | ||
| Check “Key-pad board” | Exchange the Key-pad board | ||
| 11. | The delivered volume is different from preset volume. | Check “Connection and wiring” | Modify or exchange |
| Check “CPU board” | Exchange the CPU board | ||
| Check “Key-pad board” | Exchange the Key-pad board | ||
| Check “Solenoid valve” | Modify or exchange | ||
| 12. | No petrol is delivered or slow delivery even if the motor rotated | Check “V-belt” | Confirm the tension of the V-belt |
| Check “Strainer” | Clean up the strainer in the pump unit | ||
| Check pulleys of both pump and motor | Modify the pulley | ||
| Check suction line between underground tank and pump | Modify | ||
| Check “Solenoid valve” | Exchange the solenoid valve | ||
| 13. | Counter doesn’t display. | Power is not supplied | Turn on power |
| Breaker is opened. | Seek cause and turn on. | ||
| 14. | Pump runs but doesn’t deliver oil. | Belt between motor and pump is dislocated | Set belt in place |
| No oil in underground tank | Refill with oil | ||
| 15. | Pump inoperative or no pumping | Gear and by-pass body blocked | Adjust clearance between gear and by-pass body to 0.03 to 0.06 mm. |
| Pinion and gear sucked dust and foreign particle | Repair gear and pinion | ||
| Strainer or separator sucked dust and foreign particle | Clean strainer or separator | ||
| By-pass valve inoperative a. By-pass valve blocked b. Unproper adjustment of spring | Disassemble and check a. Repair b. Adjust spring or if deformed Note: Adjust the pressure to 1.3 kg/cm2 by bolt, loosening nut. | ||
| Gear and pinion worn out. | Replace. | ||
| Control valve inoperative. | Replace. | ||
| 16. | Pouring of petrol from nozzle stand | Float valve inoperative | Adjust float valve |
| 17. | Flow meter inoperative | Water sucked | Clean piston and slide valve, dis-assembling flow meter |
| Piston blocked by dust sand or foreign particle | Clean and repair piston, disassembling flow meter. Replace, if the surface of liner or the contact between slide valve and valve seat broken. | ||
| Over-adjustment of micro-adjust. Too much adjustment of micro-adjuster to clock-wise makes flow meter inoperative. | Adjust the micro-adjuster. | ||
| 18. | Counter indication does not coincide with actual delivered volume. | Bad adjustment between slide valve and valve seat | Adjust slide valve and valve seat to have proper contact by means of lapping powder. |
| Piston packing worn out | Check each pistons and replace. | ||
| 19. | Motor does not run. | Reset lever at start position. | Set to start position. Note: If the counter cannot be reset, repair or replace counter. |
| Micro switch in relay box turned on. | Adjust nut position of switch rod. | ||
| Power supplied (AC 220V). | Check connection of junction box. Check power supply in distribution board and cable connection. | ||
| Power relay turned on. | Replace power relay. | ||
| Pump turned light by hand. | Repair according to pump repair manual. | ||
| Remove belt and check motor. | Check electrical wirings. Damage or burning of the motor. (Replacement). | ||
| 20. | Pump does not rotate or rotates with high torque. | Gear and By-pass Body blocked. | Adjust clearance. |
| Between Gear and By-pass Body clogged with dust or foreign particles. | Clean or replace. | ||
| Rotate the pump by hand if it does. | Check gear assembly. Check contact of dust or foreign particles. | ||
| 21. | Petrol does not discharge smoothly. | Separator clogged. | Clean it. |
| Strainer clogged. | Clean it. | ||
| Loose V-belt. | Adjust or replace. | ||
| 22. | Pump rotates but does not suck petrol. | No petrol in tank. | Supply it. |
| By-pass Valve inoperative. a. By-pass Valve blocked. b. Improper adjustment of By-pass Valve. | Supply it. a. Restore it. b. Adjust or run. | ||
| Strainer blocked with dust or foreign particles. | Clean it. | ||
| Too much clearance between Gear and By-pass Body. | Adjust it. | ||
| 23. | Leakage | O-ring and Gasket broken or worn out. | Replace. |
| Oil Seal broken or worn out. | Replace. | ||
| Poor tightening. | Tighten sufficiently. | ||
| 24. | It takes much time to dis-charge petrol. | Control Valve clogged with dust or foreign particles. | Clean or replace. |
| Control Valve broken. | Replace. | ||
| 25. | Spout-out of petrol from air vent pipe. | Float Valve kept closed due to deposit of dust. | Clean. |
| Ball of Ball Valve Assy disengaged. | Replace. | ||
| 26. | Slacking of belt. | Check tension and adjust the belt. | |
| 27. | Wearing of pinion or correct pitch. | Disassemble the pump by cover assembly and check pinion. | Replace pinion. Adjust pitch of pinion. |
| 28. | By-pass valve work correctly. | Disassemble and check by-pass valve. | Check movement of the by-pass valve. Check dust or trash at the by-pass valve. |
| 29. | Float valve work correctly. | Disassemble and check float room. | Check movement of the by-pass valve. Check seal and gasket if dust contacts. |
| 30. | Upper float work correctly. | Check upper float. | Check movement of the float valve. |
| 31. | Check strainer’s choking. | Check strainer. | Clean the strainer. |
| 32. | Valve work correct. | Check control valve. | |
| 33. | Display show codes & definitions “00” | No error (Cleared). | Neither displayed on the dispenser nor notified. |
| 34. | Display show codes & definitions “10”> | Erroneous signal generated from the pulse generator. | Error with more than 8 erroneous pulses. |
| 35. | Display show codes & definitions “12” | Error with the power supply for the pulse generator. | Breaks in wire, etc. |
| 36. | Display show codes & definitions “20” | Excess over the preset valve. | Excess by 60 cc. Error with the valve operations. |
| 37. | Display show codes & definitions “21” | Wrong preset range. | Less than 1L or more than 9999L. 1 |
| 38. | Display show codes & definitions “30” | Unit price is not registered. | Does not occur in coupled operation with POS. |
| 39. | Display show codes & definitions “31” | Erroneous keypad connection. | Breaks in wire or defects in the board. |
| 40. | Display show codes & definitions “40” | The registered data is corrupted. | Error in RAM. Lost communication address, if any, may inactivate notifications. |
| 41. | Display show codes & definitions “41” | The data in the electronic integrating meter/control meter are corrupted. | Error in RAM. |
| 42. | Display show codes & definitions “43” | Error in memory for fueling (dispensing) data. | Error in RAM. |
| 43. | Display show codes & definitions “ | The amount is inconsistent with the unit price multiplied by the dispensed quantity. | Error in RAM. |
| 44. | Display show codes & definitions “ | The memory does not return to zero by the reset operation. | Error in RAM. |
| 45. | Display show codes & definitions “ | The power supply fails while the nozzle is off the hanger. | |
| 46. | Display show codes & definitions “ | Erroneous operation in power-down process or the micro-computer malfunctions. | |
| 47. | Display show codes & definitions “ | Communication with POS is disrupted. | To notify when recovered. |
| 48. | Display show codes & definitions “ | Emergency stop switch has been operated. | In the device equipped with an optional emergency stop switch. |
| 49. | Display show codes & definitions “ | The oil tank is emptied. | May occur only with the oil mix dispensers. |
| 50. | Display show codes & definitions “D1” | Erroneous display (side 1) | Breaks in wire or defects in the board. |
| 51. | Display show codes & definitions “D2” | Erroneous display (side 2) | Breaks in wire or defects in the board. |